User Guide
IP Door Opening Control and SIP Interface Module
The 8061 IP Relay Controller is a SIP endpoint device which supports two functionalities:
- Door opening control for Algo 8036/8039/8201 intercoms.
- SIP interface module for the Algo 1202 Call Button.
Door Opening Control
The 8061 IP Relay Controller provides door opening control exclusively for the Algo 8036, 8039 and 8201 intercoms. The 8061 cannot be deployed as a stand alone device for door control. The 8061 serves as a bridge between the Algo intercom and peripheral hardware such as door strikes and alarm systems.
Door control functions and configurations are managed via a web interface and include:
- Access control by either entering a keypad code (e.g. 8036/8039), or by dialing a code on the answering telephone.
- The 8061 can be located in a secure environment to prevent access or tampering by outside visitors.*
* A door control relay located within a public-facing intercom itself has the potential to be compromised and thus presents a significant security issue. To address that concern, the 8061 may be located in a secure location to operate either a magnetic lock or typical door strike.
SIP Interface
Up to four 1202 Call Buttons are supported on a single 8061 controller. For an individual button press, the 8061 can play a WAV file as a SIP call or via its audio output jack. A unique WAV file can be associated with each 1202 and stored in the 8061 device memory. Only a single button press can be handled by the 8061 at a time.
Specifications
Item | Description |
Power Input | 48V PoE IEEE 802.3af Class 0 (Max 4W – Idle nominal 2W) |
Door Open Relay | Normally Open and Normally Closed, Max 30V 5A |
Door Sense Input | Not implemented at this time |
Relay Outputs | Normally Open dry contact, Max 30V 50mA |
Relay Inputs | Normally Open dry contact, Max 2 kOhm OR – configured for 1202 Call Button |
Audio Input | Not implemented at this time |
Audio Output | 0 dBm 600 Ohm 3.5 mm jack. Isolated, Line Level, Mono output. Connections provided to Tip & Sleeve. No connection to Ring if Stereo cable is used. |
Configuration | Web interface (HTTP) or auto-provisioning server |
Provisioning | TFTP, FTP, or HTTP |
Network Address | DHCP, or static IP address (recommended) |
Environmental | +32 to +122 deg F (0 to +50 deg C); suitable for dry indoor environments only. |
Compliance | RoHS, FCC Class B, CSA/UL (USA & Canada) |
Supported Algo Intercoms | 8036, 8039 and 8201 |
Dimensions | 5.75” x 7” x 1.5” |
Note: In the interests of continuing product improvement, specifications are subject to change without notice.